Slab Heat Cable In Slab Underfloor Heating System

Electric in slab underfloor heating

Slab Heat Cable is embedded in concrete floors to provide an underfloor heating solution in homes and commercial spaces with polished concrete floors.

Slab Heat Cable is suitable for new constructions and renovations as an in-slab heating system, and most popular for polished concrete floor heating. In addition to heating polished concrete floors, Slab Heat Cable is also suitable for in slab underfloor heating beneath most floor coverings including tile, carpet and timber floors.

The in-slab underfloor heating system can be used as a background heat source to complement other room heating systems, or as a stand alone in-slab storage floor heating system. Where connected to off-peak power heating rates, the slab act as a heat storage bank warming up during off-peak times (generally at night time) and releasing comfort heat during the day.

Installation of Slab Heat Cable involves installation of the heating cable to the structural steel mesh prior to the concrete pour.

Slab Heat Cable is manufactured using only the finest materials. The tough IEC compliant heating cable features a heating conductor with Fluropolymer insulation (known as Teflon) covered with a metal earth screen and Low Smoke Zero Halogen outer insulation.

Application Direct & background underfloor heating, suited for use beneath most hard & soft floor surfaces
Installation In concrete (in-slab) at least 25mm below finished floor level
Element Construction Twin heating cable, 6mm diameter with single 2m factory terminated cold tail
Voltage 240V AC
Output Power 30W/Lm
Control Analog or Digital Programmable room or floor sensing (or a combination of both) thermostat
Safety IEC60800 compliant/certified, and connection to electrical supply must conform to AS/NZS 3000 wiring regulations.
Warranty 15 Years (as of 1 February 2019)
Slab Heat 15 Range
Product Code Mat Size (mtr) Floor Area (m²) Watt @ 240V Amp @ 240V
SHC300-15 10 2.0 300 1.3
SHC450-15 15 3.0 450 2.0
SHC650-15 22 4.4 650 2.8
SHC850-15 29 5.8 850 3.7
SHC1100-15 38 7.6 1100 4.8
SHC1400-15 47 9.4 1400 6.1
SHC1700-15 57 11.4 1700 7.4
SHC2000-15 67 13.4 2000 8.7
SHC2250-15 75 15 2250 9.8
SHC2500-15 84 16.8 2500 10.9
SHC2800-15 94 18.8 2800 12.2
SHC3350-15 112 22.4 3350 14.6
SHC4000-15 134 26.8 4000 17.4
SHC4500-15 150 30 4500 19.6
SHC5000-15 168 33.6 5000 21.7

Installation of Slab Heat Cable involves installation of the heating cable to the structural steel mesh prior to the concrete pour.

  • A minimum 25mm concrete cover is required over the heating cable.
  • To achieve a heat output of 150W/m2, Slab Heat Cable must be fixed to the steel mesh at 200mm centres.
  • Heating cable fixing to steel mesh should be 400mm apart using plastic cable ties or steel clips.
  • Slab edge insulation is recommended to reduce loss of heat from the heated slab.