Mirror Demister works by ensuring that the mirror is at least 10 to 15 degrees warmer than the ambient temperature of the bathroom.
The 2mm thin self adhesive mirror heater pad is simply bonded to the back of the mirror by removing the backing paper and gently smoothing it onto the rear of the mirror.
The mirror demister is powered by a 230V connection to your bathroom light circuit, ventilation fan or together with the floor heating through a dual zone controller. When the bathroom light is switched ON (or fan or programmable controller) the mirror will warm up and keep clear while the bathroom is in use.
Application | For heating mirrors to eliminate condensation from steamy baths & showers |
Pad Construction | A thin heating element is uniformly spaced out and sandwiched between reinforced aluminium sheets. The heating element terminates to 1.8m length from one corner of the heat pad |
Element Construction | Thin 1mm single heating conductor with Teflon insulation |
Voltage | 240V AC |
Output Power | 150W/m² |
Control | Mechanical light switch, or programmable time switch, or along with Amuheat floor heating connected to a dual zone floor heating thermostatoom or floor sensing control via thermostat controller |
Safety | Connection to electrical supply must conform to AS/NZS 3000 wiring regulations. IEC60335 compliant. |
Warranty | 1 Year |
Mirror Demister 240V Range
Product Code | Pad Size (mm) | Watt @ 240V |
MDM64-15 | 600 x 400 | 36W |
MDM66-15 | 600 x 600 | 54W |
MDM68-15 | 600 x 800 | 75W |
MDM612-15 | 600 x 1200 | 108W |
Custom Sizes & Voltage
We manufacture and supply to order custom sizes and voltages for residential & commercial projects. Please contact us with your requirements. Note minimum order quantities apply.
Mirror Demister Installation Overview
- Mark out the back of the mirror to indicate where the mirror demisting pad is to be fitted and peel off the protective paper exposing the ‘sticky’ side of the mirror demister
- Position one edge of the mirror demister pad in the desired position on the keeping the other edge away from the mirror
- Gradually lower the pad onto the mirror applying even pressure to ensure there are no air bubbles or creases
- If the mirror is not framed & is being fitted directly onto the wall, a small recess will need to be made in the wall to compensate for this & allow the mirror to sit flush.
Electrical Connections
- All wiring must conform to the ASNZ3000 wiring regulations ( BS7671 equivalent)
- It is recommended that the mirror demister is connected via the lighting/ventilation circuit or on a separate switch
- The circuit should be protected by a RCD circuit
- The wires are coloured as follows: BLUE – Neutral, and BROWN – Live/positive
- The Mirror Demister pad must not be accessible once installed
- Any metal part surrounding the mirror must be earthed & comply with current wiring regulations
- Multiple mirror demisters may be fitted to a single mirror & should be connected in parallel – pads must not overlap
- The mirror demister pad must not be cut or pierced as this may damage the insulation making it unsafe