Cable Mat PDF E-mail

Amuheat Cable Mat Floor Heating System


Overview


Cable Mat Floor Heating - Amuheat Electric & Hydronic Underfloor Heating Australia

The Cable Mat floor heating system is suited for in tile-adhesive, thinset or in-screed floor heating applications directly beneath tile, stone, floating and timber floor finishes. Suitable sub-floors include concrete slabs, suspended timber, F/C sheet floors or existing tiles.

Cable Mat comprises of a flexible heating element uniformly looped and fixed onto a flexible, robust fiberglass mat. The floor heating systems construction and installation methodology does not require any special tools and is quickly stuck to a clean subfloor using the attached adhesive tape strips. The ease of installation also makes them an ideal ‘Do-it-Yourself” or Trade kit without requirements or experience for planning their layouts.


Features


  • Quick response time - within 30 minutes in tile adhesive
  • Available in kit form for trade or DIY install
  • Waterproof - safe in wet areas
  • Fully earthed and Teflon insulated floor heating element
  • Maintenance free
  • Energy efficient heating system
  • Thermostatically controlled
  • Allergy friendly - produces no VOC's (Volatile Organic Compounds)
  • Healthy, produces no harmful EMR (Electro Magnetic Radiation)
  • 10 Year warranty (including DIY & Trade supply)

Technical



Floor Heating System
Application: Direct & background heating for installation over concrete or F/C sheet floors. The mat is embedded in tile adhesive, thinset or in-screed directly beneath most hard floor finishes including tile, floating and timber floors.
Cable Mat Construction: Comprises of a flexible, robust fiber-glass mat with the looped heating element uniformly fixed on it. The heating element terminates to 3m length cold leads at both ends of the mat.
Heating Element: Self regulating single heating conductor with Teflon insulation, protected by a metal earth shield with a second insulation sheath.
Voltage: 240 Volt AC
Output Power: From 150 to 200W/m²
Under Floor Heating ThermostatControl: Programmable room or floor sensing (or a combination of both) control
Safety: IEC60335 compliant and wired into an earthed power supply connected through a RCD circuit. Safe in wet areas.
Quality: DIN EN ISO 9001:2000 standards
Approvals: SEMKO & UL certified
Cable Mat Warranty: 10 years




Installation



Tile & Stone Installations
Installation of Cable Mat is a simple process offering reduced installation time. After the subfloor has been prepared (cleaned and in some cases primed with a bonding agent), the cable mat is rolled out and stuck to the floor using the attached adhesive tape strips. The flooring can be immediately installed after the element fault monitor is connected to the cold tail leads.
Cable Mat Floor Heating Installation

Cable Mat is easily configured on-site to suit any floor layout
Cable Mat Floor Heating

Laminates & Vinyl
Following the installation instructions as per tile and stone heating, Cable Mat should be covered with a 4-5mm self-levelling screed. This will ensure the floor is smooth and level for the laminate, bamboo or vinyl flooring. Once the screed has cured, flooring can be immediately installed after the element fault monitor is connected to the cold tail leads.

Timber
Cable Mat can be installed between battens of a minimum height of 5mm on the subfloor (concrete, plywood or F/C Sheeting). Once the battens have been fixed to the floor at 500mm intervals, Cable Mat is installed between the battens as per tile and stone installation instructions. It is important to cover the Cable Mat with screed up to and even with the top of the timber battens. Once the screed has cured, flooring can be immediately installed after the element fault monitor is connected to the cold tail leads. The hardwood floor should only be nailed into the timber battens.


Solutions



Amuheat offers full-service support, working closely with specifiers, engineers, builders, electrical trades, flooring contractors and homeowners during all stages of construction including:
  • Design & specification
  • Trade co-ordination and liason
  • Technical support pre and during construction
  • Installation through a network of franchise agents across Australia
  • Post technical support for users


Trade Kits



Cable Mat floor heating kits are supplied complete for a succesful DIY & Trade install. Kits include:
  • Floor Heating KitCable Mat heater w/terminated cold tails
  • Element fault monitor
  • Digital programmable thermostat with built in timer & air sensor
  • Floor probe sensor
  • Installation guide
  • Free design & layout service
  • Telephonic technical & installation support


Bathroom Floor Heating Kits - 200W/m2
Bathroom Floor Heating Kits


Room Heating Kits - 150W/m2
Room Floor Heating Kits


Downloads



    Cable Mat Installation Guide
          (in-tile adhesive, levelling componds & in-screed)

    Electrical Requirements for Electric Floor Heating

   Cable Mat Floor Heating Data Specification 
          (in-tile adhesive, levelling componds & in-screed)

    AT908 Thermostat Operating Guidelines
          (programmable thermostat with built in timer, air sensor & remote floor sensor)

    ETV1991 Thermostat Operating Guidelines
          (manual thermostat for DIN Rail mounting with remote floor sensor)



For DIY/Trade supply or professional installation enquiries, contact Amuheat Design on (02) 9114 6934 or upload your request and plans through our website.